UK Caravanning (uk.rec.caravanning) A forum for the discussion of caravanning undertaken by residents of the United Kingdom, whether in the UK or abroad. It encourages the interchange of views on the merits of models of caravan, makes of tow car, accessories, caravan sites, caravan clubs, and other related topics. The term caravan is to include trailer vans, motor caravans and trailer tents.

Help please :MORCO WATER HEATER



 
 
LinkBack Thread Tools Display Modes
  #1 (permalink)  
Old August 10th 05, 09:45 AM posted to uk.rec.caravanning
Long tall ugly
external usenet poster
 
Posts: 158
Default Help please :MORCO WATER HEATER

Hi All,

Could use some help with my water heater.

Van is a 84 Compass Commadore 420/2 SE
Water Heater is a MORCO SH-180

Problem is :-FFD is not holding
Fault traced to sealed switch (on bottom l/h side of water tank).

FFD is giving 5ma up to sealed switch inline connector but nothing
out the other side. The sealed switch is showing continuity so
therefore I should see 5ma at the other side but i don't.

If I bridge the inline connector then the FFD feeds to the solenoid
in the gas valve and all workds OK.

Question:

What is the sealed switch for ? Is it a water pressure switch.?
could I by pass it ?

I realy do not want to change the heater as I am trying to keep the
van as original as poss.

Thanks for any help

John

john at twws dot gotadsl dot co dot uk
Ads
  #2 (permalink)  
Old August 10th 05, 12:06 PM posted to uk.rec.caravanning
clive
external usenet poster
 
Posts: 3
Default Help please :MORCO WATER HEATER


"Long tall ugly" wrote in message
...
Hi All,

Could use some help with my water heater.

Van is a 84 Compass Commadore 420/2 SE
Water Heater is a MORCO SH-180

Problem is :-FFD is not holding
Fault traced to sealed switch (on bottom l/h side of water tank).

FFD is giving 5ma up to sealed switch inline connector but nothing
out the other side. The sealed switch is showing continuity so
therefore I should see 5ma at the other side but i don't.

If I bridge the inline connector then the FFD feeds to the solenoid
in the gas valve and all workds OK.

Question:

What is the sealed switch for ? Is it a water pressure switch.?
could I by pass it ?

I realy do not want to change the heater as I am trying to keep the
van as original as poss.

Thanks for any help

John

john at twws dot gotadsl dot co dot uk


I think you may have some errors in your information.

You say 5mA to the switch. To get a current reading your meter needs to be
connected in series. You'll only get a current reading when current flows...
to an item like a lamp or a valve, or even a fault.

I think you need to re-test using a voltage setting (connecting in
parallel), and measure for voltage to the switch, and leaving the switch.

You can use an ammeter (amps not volts) to see if you have an output from
your thermocouple when heated.


  #3 (permalink)  
Old August 10th 05, 12:06 PM posted to uk.rec.caravanning
clive
external usenet poster
 
Posts: 1
Default Help please :MORCO WATER HEATER


"Long tall ugly" wrote in message
...
Hi All,

Could use some help with my water heater.

Van is a 84 Compass Commadore 420/2 SE
Water Heater is a MORCO SH-180

Problem is :-FFD is not holding
Fault traced to sealed switch (on bottom l/h side of water tank).

FFD is giving 5ma up to sealed switch inline connector but nothing
out the other side. The sealed switch is showing continuity so
therefore I should see 5ma at the other side but i don't.

If I bridge the inline connector then the FFD feeds to the solenoid
in the gas valve and all workds OK.

Question:

What is the sealed switch for ? Is it a water pressure switch.?
could I by pass it ?

I realy do not want to change the heater as I am trying to keep the
van as original as poss.

Thanks for any help

John

john at twws dot gotadsl dot co dot uk


I think you may have some errors in your information.

You say 5mA to the switch. To get a current reading your meter needs to be
connected in series. You'll only get a current reading when current flows...
to an item like a lamp or a valve, or even a fault.

I think you need to re-test using a voltage setting (connecting in
parallel), and measure for voltage to the switch, and leaving the switch.

You can use an ammeter (amps not volts) to see if you have an output from
your thermocouple when heated.


  #4 (permalink)  
Old August 10th 05, 12:25 PM posted to uk.rec.caravanning
Long tall ugly
external usenet poster
 
Posts: 158
Default Help please :MORCO WATER HEATER

On Wed, 10 Aug 2005 10:45:07 +0100, Long tall ugly
wrote:
Thanks for the reply Clive,

Sorry didn't make myself clear...I tested the thermocouple 'in series
to ground ' to establish the current...I'm thinking that the sealed
switch, though showing no resistance, is leaking off the current from
the thermo couple.

John

Hi All,

Could use some help with my water heater.

Van is a 84 Compass Commadore 420/2 SE
Water Heater is a MORCO SH-180

Problem is :-FFD is not holding
Fault traced to sealed switch (on bottom l/h side of water tank).

FFD is giving 5ma up to sealed switch inline connector but nothing
out the other side. The sealed switch is showing continuity so
therefore I should see 5ma at the other side but i don't.

If I bridge the inline connector then the FFD feeds to the solenoid
in the gas valve and all workds OK.

Question:

What is the sealed switch for ? Is it a water pressure switch.?
could I by pass it ?

I realy do not want to change the heater as I am trying to keep the
van as original as poss.

Thanks for any help

John

john at twws dot gotadsl dot co dot uk

  #5 (permalink)  
Old August 10th 05, 12:25 PM posted to uk.rec.caravanning
Long tall ugly
external usenet poster
 
Posts: 158
Default Help please :MORCO WATER HEATER

On Wed, 10 Aug 2005 10:45:07 +0100, Long tall ugly
wrote:
Thanks for the reply Clive,

Sorry didn't make myself clear...I tested the thermocouple 'in series
to ground ' to establish the current...I'm thinking that the sealed
switch, though showing no resistance, is leaking off the current from
the thermo couple.

John

Hi All,

Could use some help with my water heater.

Van is a 84 Compass Commadore 420/2 SE
Water Heater is a MORCO SH-180

Problem is :-FFD is not holding
Fault traced to sealed switch (on bottom l/h side of water tank).

FFD is giving 5ma up to sealed switch inline connector but nothing
out the other side. The sealed switch is showing continuity so
therefore I should see 5ma at the other side but i don't.

If I bridge the inline connector then the FFD feeds to the solenoid
in the gas valve and all workds OK.

Question:

What is the sealed switch for ? Is it a water pressure switch.?
could I by pass it ?

I realy do not want to change the heater as I am trying to keep the
van as original as poss.

Thanks for any help

John

john at twws dot gotadsl dot co dot uk

 



Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT. The time now is 07:02 AM.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2019, Jelsoft Enterprises Ltd.Content Relevant URLs by vBSEO 3.0.0 RC6
Copyright 2004-2019 Caravan Banter.
The comments are property of their posters.